Programming Notes
Entering Voice Prompt Programming
Power-up the control and enter the Installer Code + 8 8 8.
When you have completed each programming procedure
the system will return to the Main Programming Menu.
Exiting Voice Prompt Programming
Once you have returned to the Main Programming Menu,
press the ESCAPE/ OFF key.
Entering Central Station Phone Numbers
Enter 0-9, #+11 = 7, #+12 =#, #+13 = a pause of 2
seconds.
Entering Central Station Account Numbers
Enter 0-9, #+11=B, #+12 =C, #+13=D, #+14=E,
#+15=F
Programming Zone Types
The Voice Prompt Programming feature can not be used to
program Zone Types 02, 05, 10, 14, and 24. Programming
these zone types must be done using the Expert
Programming Mode.
5. Voice Prompt Programming
Navigating the Voice Prompt Programming Mode
Scroll through the voice menu and follow the instructions provided to
continue using the Voice Prompt Programming Mode.
The following keys are used to navigate through this feature.
1. ESCAPE/ OFF key: Used at any time to exit the current menu and return
to the previous prompt.
2. ADD/ AWAY key: Used to add sensors or keys or save data when
entering phone or account numbers.
3. DELETE/ STAY key: Used to delete a sensor when in the delete
Sensors Menu.
4. SELECT/ AUX key: Used to confirm a selection.
5. 3 key: Used to scroll forward through menu choices.
6. 6 key: Used to scroll backward through menu choices.
7. FUNCTION/ # key: Used to repeat a voice prompt.
(This function cannot be used while entering phone or account numbers.)
1000-300-012-V0
ARMED READY
BYPASS
NO DELAY
RECORD
TEST
FUNCTION
STATUS
VOLUME
PLAY
CODE
LIGHTS ON
LIGHTS OFF
CHIME
ESCAPE
ADD
DELETE
SELECT
1 2
4 5
7
8
0
OFF
AWAY
1
2
STAY
AUX
6
9
3
5
6
7
3
4
6a. Add Sensors
The Lynx Plus Series will enroll a sensor once the transmitter has been activated two times. The system will confirm the enrollment
following each subsequent activation of the same transmitter.
Add a Door Sensor
(1) Delay Door Location
Front Back Side Garage Basement
Sliding Hall Kitchen Patio
Add a Window, Motion Detector, or Fire Detection Sensor
(2) Sensor Type (3) Sensor Location (4) Location Modifiers
Window
Living room
Kitchen
Family Room
Upstairs
Second Floor
Motion Detector Dining room Hall Guest Room Office Downstairs Front
Fire Detection Bedroom Basement Laundry Room Upstairs First Rear
Bathroom Master Bedroom Utility Room Second Side
Nursery Den Garage Third
6a. Add Sensors (Continued)
Add an Emergency Pendant
(5) Pendant Type
Medical Fire Silent Police Police
Add a Wireless Key
When adding wireless keys, wait 5 seconds between
transmissions.
6b. Delete Sensors
Delete Sensors
7. Add Central Station Accounts
Add First Central Station Phone Number
Add First Central Station Account Number
All four digits of the Central Station Account numbers must be
entered. For ten-digit format, all ten digits must be entered.
Refer to the Lynx Plus Series Installation and Setup Guide for
additional information regarding these programming options.
Add Second Central Station Phone Number
Add Second Central Station Account Number
8. Program Additional Options
Enter Expert Programming Mode
Once you have entered the Expert Programming Mode, the
[ESCAPE] key can be used to return to the Voice Prompt
Programming mode. If you are in any of the Interactive Menu
Modes (756, 780, 781, 783, 784 or 785), you must return to
the main menu in that field before pressing the [ESCAPE] key.
The Lynx Plus Series is configured with Factory Default Settings. You
can revise these settings using the Expert Programming Mode. Refer
to the Installation and Setup Guide to view these defaults and to
continue programming the individual fields using this mode.
Exit Expert Programming Mode
When programming is complete, enter 799.
9. Perform Go/No Go Test
Temporarily mount wireless devices in the preferred mounting
location and perform a Go/No Go test to ensure adequate signal
strength is available.
1. Enter Installer Code + [#] + [8] and run Go/No Go Test.
2. Fault each transmitter to ensure all programmed zones are
received.
3. Mount the transmitter in its permanent location.
10. Program User Functions
Set the Real-Time Clock
1. Enter the Installer Code + FUNCTION/ # + 63
2. Follow the Voice Prompts to program the Clock/Calendar.
Change the Master User Code
1. Enter the Installer Code + CODE/ 8 + 02 + desired 4-digit Master
Code.
Add User Codes
1. By following the procedures in the Lynx Plus Series User Guide,
show the User how to add additional User Codes.
11. Test the system
1. Enter the User Code+ TEST key. The external sounder will sound
for two seconds and all the LCD segments on the keypad display
light for 3 seconds.
2. Open each protected door and listen for three beeps from the
keypad, followed by the zone’s Voice Descriptor. Identification of
each faulted protection point should appear on the display, and
clear when the door is closed.
3. Walk in front of the motion sensor and listen for three beeps and
the zone’s voice descriptor.
4. When testing is complete, enter: User Code + OFF key.
5. Press each key on the key fob to confirm it performs its assigned
function.
Note: Refer to the Lynx Plus Series User Guide for additional information.